Noise Reduction - ATCO Noise Management Noise Suppression and acoustical consultants
Noise Pollution - Corporate Commitment Industrial Noise Control - Careers Acoustic Solution - ATCO Group
Noise Mitigation - ATCO Logo
Home Search for Noise Control Information Site Map Contact Acoustical Consulting Experts Higgott-Kane, A Division of ATCO Noise Management
Noise Abatement - ATCO Logo
Acoustic Consulting- Profile Suppression System -  Products & Services Acoustic Barriers - Industry Solutions Noise Reduction - Project Library Noise Pollution - Media Room Acoustical Engineering - Industry Events
Noise Abatement
Industrial Noise Control Examples Industrial Noise Control Success Stories  
Noise Control for Power Generation
Noise Control for Oil and Gas
Noise Control for Petrochemical
Noise Control for Petrochemical
Noise Control for Original Equipment Manufacturers
Noise Control for Retrofit
Noise Control for Light Rail Transit (LRT)
Noise Control for Other Noisy Industries

Williams Gas Pipeline
Acoustical retrofit for gas compressor buildings

General Description:
The lube oil cooler and exhaust stacks were causing particular noise problems at two existing compressor stations for Williams Gas Pipeline - Transco. ATCO Noise Management provided a unique system at each station to silence the lube oil cooler intake and discharge but did not reduce the air flow. The existing air flow had to be maintained to cool the engines and compressors.

Noise from the lube oil cooler was lowered with a pressure drop of only 0.016 inches W.G. (Water Gauge)- well within the allowable level. The lube oil pipes were isolated to stop vibration from radiating through the structure. Inserting silencing baffles treated the exhaust stack. By treating the original stack instead of replacing it, the client realized a considerable cost saving. As well, ATCO Noise Management's Type B acoustical wall was applied to certain existing wall sections to reduce the amount of noise transmitted into the surrounding environment. All acoustical work was done to comply with FERC (Federal Energy Regulatory Commission) regulations.

Client:
Williams Gas Pipeline - Transco
Houston, Texas

Project Locations:
Monroe, Georgia (Station 125)
Rockford, Alabama (Station 105)

Technical Information:
One (1) Solar Mars 100S Turbine
Original source noise levels at Station 105 were 45 dBA at the Nearest Sensitive Area (NSA) at 650 feet.

Acoustical Requirements:
40 dBA at 650 feet from building

Original source noise levels at station 125 were 46 dBA at the NSA (650 feet).

Acoustical requirements:
39.6 dBA at 650 feet from building

<< back to Retrofit Index
<< Download pdf for Station 125 here
<< Download pdf for Station 105 here

Noise reduction for Solar Mars 100S turbine

 

Acoustic Retrofit for Solar Mars 100S Turbine