Cooper
Energy Services
Acoustical
off-skid enclosures for gas compressor buildings
General
Description:
ATCO Noise Management Ltd. designed, supplied, and erected
four off-skid acoustical enclosures, containing acoustical ventilation
systems complete with fans, ventilation intake and exhaust
silencers, and lube oil silencer. Acoustical equipment doors
were utilized in conjunction with an innovative, exterior
crane system designed for removal of the turbine or compressor
for maintenance. ATCO Noise Management also supplied auxiliary
fire suppression, fire and gas detection, electrical systems,
and utility buildings at each station.
Supplier:
Cooper Energy Services
Mount Vernon, Ohio
Owner:
TransCanada PipeLines Ltd.
Calgary, Alberta, Canada
Project
Locations:
Spruce, Manitoba, Canada
Kenora, Ontario, Canada
Upsala, Ontario, Canada
Kapuskasing, Ontario, Canada
Technical
Information:
Rolls-Royce DLE Turbocompressor packages
Original source noise levels: 120 dBA
Acoustical
requirements:
varied from 40 - 51 dBA at 100 metres
<< back to OEM Index
<< Download pdf here |