Noise Reduction - ATCO Noise Management Noise Suppression and acoustical consultants
Noise Pollution - Corporate Commitment Industrial Noise Control - Careers Acoustic Solution - ATCO Group
Noise Mitigation - ATCO Logo
Home Search for Noise Control Information Site Map Contact Acoustical Consulting Experts Higgott-Kane, A Division of ATCO Noise Management
Noise Abatement - ATCO Logo
Acoustic Consulting- Profile Suppression System -  Products & Services Acoustic Barriers - Industry Solutions Noise Reduction - Project Library Noise Pollution - Media Room Acoustical Engineering - Industry Events
Noise Abatement
Industrial Noise Control Examples Industrial Noise Control Success Stories  
Noise Control for Power Generation
Noise Control for Oil and Gas
Noise Control for Industrial Gas Production
Noise Control for Petrochemical
Noise Control for Original Equipment Manufacturers
Noise Control for Retrofit
Noise Control for Light Rail Transit
Noise Control for Other Noisy Industries

Iroquois Gas Transmission
Acoustical buildings

General Description:
A unique assignment for ATCO Noise Management involved noise abatement for Iroquois Gas Transmission's Wright, New York station. The station not only had to achieve a design goal of 42 dBA, monitored at 300 feet but it had to blend in with the rural countryside. ATCO Noise Management treated each significant noise source - gas turbines and compressors, combustion intake and exhaust, lube oil cooler, cooling and ventilation fans - then built the station buildings to look like barns. Wright's station is barn red with cupolas, a weather vane and exhaust stacks that resemble farm grain silos.

Customer:
Iroquois Gas Transmission System
Shelton, CT Project

Location:
Wright, New York, USA

Technical Information:
2 - Solar 5650-hp Centaur 50 turbines each driving a Solar C337 compressor.

Source noise levels expected:
93 dBA

Acoustical requirements:
42 dBA at 300 feet distance from the building
20 dBA minimum reduction in each octave band

Actual performance results:
38 dBA at 100 feet distance
20 dBA minimum reduction in each octave band

<< back to Oil & Gas Index
<< Download pdf here

Acoustical building and acoustical architecture for Iroquois Gas Transmission

Overall view of acoustical buildings at Wright, NY

 

Noise abatement for gas turbine

Close up view of one of the buildings

 

Acoustic buildings for Iroquois Gas Transmission

Close up view showing cupolas

 

Home | Search | Site Map | Contact Us | ATCO Group | Higgott-Kane, a Division of ATCO Noise Management | ATCO Acoustical Consultants | Legal | Privacy | Web Privacy
Company Profile | Products & Services | Industry Solutions | Project Library | Media Room | Industry & Events